Ethyl acetate, SupraSolv® for GC-ECD/FID, Supelco®
Supplier: MilliporeSigma
|
Danger
|
Synonyms:
EtOAc
, Acetidin
, Ethyl ethanoate
, Vinegar naphtha
, Ethyl acetic ester
, Acetic acid ethyl ester
, Acetic ether
, Acetoxyethane
M-Clarity™ quality level = MQ100
SupraSolv® ECD and FID is specially developed for gas chromatography in combination with ECD (Electron Capture Detetor) and FID (Flame Ionization detector). SupraSolv® solvents offer the largest specified retention time range, a clear baseline and a minimal signal-to-noise ratio leading to reliable and reproducible analysis results.
Formula:
CH₃COOC₂H₅ MW: 88.11 g/mol Boiling Pt: 77.1 °C (1013 hPa) Melting Pt: –83 °C Density: 0.902 g/cm³ (20 °C) Flash Pt: –4 °C Storage Temperature: Ambient |
MDL Number:
MFCD00009171 CAS Number: 141-78-6 EINECS: 205-500-4 UN: 1173 ADR: 3, REACH: 01-2119475103-46 Merck Index: 13,03792 |
Specification Test Results
Solubility | 85.3 g/l (20 °C) |
Melting Point | -83 °C |
Molar Mass | 88.11 g/mol |
Boiling Point | 77 °C (1013 hPa) |
Vapor Pressure | 97 hPa (20 °C) |
Flash Point | -4 °C |
Refractive Index | 1.37 |
Explosion Limit | 2.1 - 11.5 %(V) |
Density | 0.90 g/cm3 (20 °C) |
pH | (H2O) no data available |
Ignition Point | 460 °C |
Hazard Class | 3 |
Hazard Class Description | Flammable liquid |
Learn more